Fault Identification/Operator Warning:
S  Do troubleshooting by connecting one of the follow-
ing devices to the loopback connector:
S  Alerts operator to several potential  problems with
audible “beeps” and/or by cutting unit shut down.
Diagnostics:
-
-
Diagnostic ACE (with the correct overlay).
TOROPC and a personal computer
(authorized Toro distributor only).
Understanding the Diagnostic Lamps
Red Diagnostic Lamp
(located on steering tower)
Functions:
S  ON
-
When glow plug circuit is energized.
S  FLASHING
-
When electronic controller has sensed an output
fault (for RM 6700-D, observe the green diagnotic
lamps under control console to determine which
controller is sensing the fault).
1
Figure 7
Red Diagnostic Light
-
-
When  the operator  has exceeded  the  optional
programmed speed limit.
When optional TurfDefender leak detector has de-
tected a hydraulic leak.
1.
1
S  OFF
-
-
-
-
-
-
When monitored circuits are functioning properly.
When ACE Diagnostic Tool is connected.
When Loop-back connector is disconnected.
When thereisnopowertotheelectronic    controller.
When the lamp bulb is burned out.
When no  software is  installed or  the electronic
controller is not functioning properly.
Diagnostics:
Figure 8
S  Check electrical connections, input fuses and diag-
1.  Green Diagnostic Light (RM 6500-D shown)
nostic light bulb to determine malfunction.
S  FLASHING
S  Make sure loop-back connector is secured to wire
harness connector.
(Red diagnostic lamp not flashing - RM 6700-D)
-  When  primary  electronic controller  or  primary
controller software is not functioning properly.
S  Connect ACE Diagnostic Tool and check controller
input and output functions.
-
When CAN (Controller Area Network) Bus is not
functioning properly.
S  Check optional  TurfDefender  leak  detector (see
Leak  Detector  Operation  in  this  section  of this
manual).
S  OFF
-
-
-
-
When ACE Diagnostic Tool is connected.
When Loop-back connector is disconnected.
When thereisnopowertotheelectronic    controller.
When the lamp bulb is burned out.
Green Diagnostic Lamp
(one per controller located under control console)
Functions:
- When  no software  is installed  or the electronic
controller is not functioning properly.
Diagnostics:
S  ON
-
When controller software  is successfully loaded
andallmonitoredcircuitsarefunctioningproperly.
S  Check electrical connections, input fuses and diag-
nostic light bulb to determine malfunction.
S  FLASHING
(Red diagnostic lamp also flashing)
S  Connect ACE Diagnostic Tool and check controller
input and output functions.
-
When electronic controller has sensed an output
fault.
S  Check optional  TurfDefender  leak  detector (see
Leak  Detector  Operation  in  this  section  of this
manual).
Reelmaster 6500-D/6700-D
Electrical System (Rev. C)
Page 5 - 5
Product Specification
CategoriesLawn Mower Manual, Toro Lawn Mower Manual
Tags,
Download File
Please Enter the Security Characters Shown Below. Letters are Case Sensitive. Your download link will appear upon completing this step.
- 328 pages
Document TypeService Manual
LanguageEnglish
Product BrandToro. Customer Service Representatives are available by phone: Monday - Friday 7:30 a.m. to 9:00 p.m. (CDT) - Saturday 8:00 a.m. to 8:00 p.m. (CDT) - Sunday 10:00 a.m. to 8:00 p.m. (CDT)
Canada 1-888-225-4886 USA 1-888-384-9939, Lawn Mower
Product TypeWalk Behind Mower
Engine ManufacturerToro
Document File TypePDF
Publishertoro.com
Wikipedia's PageToro Company
CopyrightAttribution Non-commercial
(0 votes, average: 0 out of 5)

Submit your review (optional)
(will not be displayed)
* Required Field

Leave a Reply

Your email address will not be published. Required fields are marked *

*
*
Website