Cutting Unit Operating Problems
Problem
Possible Causes
The cutting units remain engaged, but should not, with    The seat sensor or circuit wiring is faulty.
no operator in the seat.
Cutting units run, but should not, when raised. Units
shut off with enable disable switch.
The front reels down sensor or circuit wiring is faulty.
Cutting units run, but should not, when raised. Units do   Both the front reels down sensor or circuit wiring, and
not shut off with the enable disable switch.
enable/disable switch or circuit wiring are faulty.
A hydraulic problem exists (see Troubleshooting
section of Chapter 4 - Hydraulic System).
None of the cutting units operate in either direction.
Units are able to raise and lower.
The seat sensor actuator is lifting off the seat switch.
The seat sensor or circuit wiring is faulty.
The enable/disable switch or circuit wiring is faulty.
The front reels down sensor or circuit wiring is faulty.
Ground circuit wiring to solenoids may be open.
A hydraulic problem exists (see Troubleshooting
section of Chapter 4 - Hydraulic System).
Cutting units run, but should not, when lowered with
enable/disable switch in the disable position.
The enable/disable switch or circuit wiring is faulty.
The front cutting units do not operate in either
direction. Units are able to raise and lower. Rear
cutting units operate.
Solenoid MSV1 or circuit wiring is faulty.
A hydraulic problem exists (see Troubleshooting
section of Chapter 4 - Hydraulic System).
The rear cutting units do not operate in either direction.   Solenoid MSV2 or circuit wiring is faulty.
Units are able to raise and lower. Front cutting units
A hydraulic problem exists (see Troubleshooting
operate.
section of Chapter 4 - Hydraulic System).
The rear cutting units #6 and/or #7 (RM 6700-D Only)     Solenoid S10 and/or S11 or circuit wiring is faulty.
do not operate in either direction. Units are able to
A hydraulic problem exists (see Troubleshooting
section of Chapter 4 - Hydraulic System).
raise and lower. Front cutting units and remaining rear
cutting units operate.
None of the cutting units will lower.
Lower/mow switch on joystick or circuit wiring is faulty.
Reel Enable/Disable Switch in middle position.
Solenoid SV1 or circuit wiring is faulty.
Solenoid SV8 (if equipped) or circuit wiring is faulty.
A hydraulic problem exists (see Troubleshooting
section of Chapter 4 - Hydraulic System).
Outer front cutting units #4 and 5 will not lower.
Reelmaster 6500-D/6700-D
Flow divider FD1 solenoid (if equipped) or circuit wiring
is faulty.
A hydraulic problem exists (see Troubleshooting
section of Chapter 4 - Hydraulic System).
Electrical System (Rev. C)
Page 5 - 15
Product Specification
CategoriesLawn Mower Manual, Toro Lawn Mower Manual
Tags,
Download File
Please Enter the Security Characters Shown Below. Letters are Case Sensitive. Your download link will appear upon completing this step.
- 328 pages
Document TypeService Manual
LanguageEnglish
Product BrandToro. Customer Service Representatives are available by phone: Monday - Friday 7:30 a.m. to 9:00 p.m. (CDT) - Saturday 8:00 a.m. to 8:00 p.m. (CDT) - Sunday 10:00 a.m. to 8:00 p.m. (CDT)
Canada 1-888-225-4886 USA 1-888-384-9939, Lawn Mower
Product TypeWalk Behind Mower
Engine ManufacturerToro
Document File TypePDF
Publishertoro.com
Wikipedia's PageToro Company
CopyrightAttribution Non-commercial
(0 votes, average: 0 out of 5)

Submit your review (optional)
(will not be displayed)
* Required Field

Leave a Reply

Your email address will not be published. Required fields are marked *

*
*
Website