Mow and Backlap
Mow
On the circuit supplied by pump section (P2), maximum
system pressure is limited by relief valve (R2), which is
set at 2000 PSI (138.0 bar) on Reelmaster 6500--D and
The reel manifold contains two independent control cir-
cuits for the front and rear cutting units. Each circuit is
supplied by its own gear pump section. Gear pump sec-
tion (P1) supplies hydraulic power to the front cutting
units, while section(P2) supplies thetherear units.Both
circuits share manifold port (T), which drains to the oil
cooler, oil filter, and on to the hydraulic reservoir.
3000
PSI (207.0 bar) on Reelmaster 6700--D. Solenoid
valve (MSV2) must be energized to prevent hydraulic
flowfromby-passingtherearreelcircuit.Whensolenoid
valve (MSV2) is energized, oil flow from port (P2) flows
through reel speed control valve (FC2). Flow through
the speed control valve is pressure compensated by
logic cartridge valve (LC2). The logic cartridge valve
maintains a pressure of 75 PSI (5.2 bar) across the
speed control valve. Any excess flow is returned to the
hydraulic reservoir. Regulated flow continues through
valve (MD2) and out to the rear reel motors. On Reel-
master 6700-D, two solenoid valves (S10) and (S11) di-
rectoilflowtocuttingunits#6and#7.Whenvalve(MD2)
is in the “Mow” position, the rear reels rotate correctly
for mowing. Return oil from the motors is also directed
to the reservoir through valve (MD2).
On the circuit supplied by pump section (P1), maximum
system pressure is limited by relief valve (R1), which is
set at 3000 PSI (207.0 bar). Solenoid valve (MSV1)
must be energized to prevent hydraulic flow from by-
passing the front reel circuit. When solenoid valve
(MSV1) is energized, oil flow from port (P1) flows
through reel speed control valve (FC1). Flow through
the speed control valve is pressure compensated by
logic cartridge valve (LC1). The logic cartridge valve
maintains a pressure of 75 PSI (5.2 bar) across the
speed control valve. Any excess flow is returned to the
hydraulic reservoir. Regulated flow continues through
valve(MD1)andouttothefrontreelmotors.Whenvalve
(MD1)isinthe“Mow”position,thefrontreelsrotatecor-
rectly for mowing. Return oil from the motors is also di-
rected to the reservoir through valve (MD1).
System pressure on the (P2) side can be measured at
Port (G2).
Backlap
During the backlap mode of operation, the reel circuits
operate the same as in the ”Mow” mode. When either
valve (MD1) or (MD2) is set to the “Backlap” position,
thevalvereversesthedirectionofhydraulicflowthrough
the reel motors, and the reels rotate correctly for back-
lapping.
System pressure on the (P1) side can be measured at
Port (G1).
Reelmaster 6500-D/6700-D
Page 4 - 21 Rev. C
Hydraulic System
Categories | Lawn Mower Manual, Toro Lawn Mower Manual |
---|---|
Tags | Toro Reelmaster 6500-D, Toro Reelmaster 6700-D |
Download File |
|
Document Type | Service Manual |
Language | English |
Product Brand | Toro. Customer Service Representatives are available by phone:
Monday - Friday 7:30 a.m. to 9:00 p.m. (CDT) - Saturday 8:00 a.m. to 8:00 p.m. (CDT) - Sunday 10:00 a.m. to 8:00 p.m. (CDT)
Canada 1-888-225-4886 USA 1-888-384-9939, Lawn Mower |
Product Type | Walk Behind Mower |
Engine Manufacturer | Toro |
Document File Type | |
Publisher | toro.com |
Wikipedia's Page | Toro Company |
Copyright | Attribution Non-commercial |
(0 votes, average: 0 out of 5)