Testing
The most effective method for isolating problems in the
hydraulic system is by using hydraulic test equipment
such as pressure gauges and flow meters in the circuits
during various operational checks (See the Special
Tools section in this Chapter.)
WARNING
Keepbodyandhandsawayfrompinholeleaks
or nozzles that eject hydraulic fluid under high
pressure. Do not use hands to search for
leaks; use paper or cardboard. Hydraulic fluid
escaping under pressure can have sufficient
force to penetrate the skin and cause serious
injury. If fluid is injected into the skin, it must
be surgically removed within a few hours by a
doctor familiar with this type of injury. Gan-
grene may result from such an injury.
Before Performing Hydraulic Tests
IMPORTANT: All obvious areas such as oil supply,
filter,bindinglinkages, loosefasteners, orimproper
adjustmentsmustbecheckedbeforeassumingthat
ahydrauliccomponentisthesourceoftheproblem.
Precautions for Hydraulic Testing
1.
Clean machine thoroughly before disconnecting or
CAUTION
disassembling any hydraulic components. Always keep
in mind the need for cleanliness when working on hy-
draulic equipment. Contamination will cause excessive
wear of components.
Failure to use gauges with recommended pres-
sure (psi) rating as listed in test procedures
couldresultindamagetothegaugeandpossible
personal injury from leaking hot oil.
2.
open or exposed during testing or removal of compo-
nents.
Put metal caps or plugs on any hydraulic lines left
CAUTION
3.
Theenginemustbeingoodoperatingcondition.Use
a phototac when performing a hydraulic test. Engine
speed can affect the accuracy of the tester readings.
Check actual speed of the pump when performing flow
testing.
All testing should be performed by two (2)
people.Onepersonshouldbeintheseattooper-
ate the machine, and the other should read and
record test results.
4.
The inlet and the outlet hoses must be properly con-
nected and not reversed (tester with pressure and flow
capabilities)topreventdamagetothehydraulictesteror
components.
CAUTION
5.
ties, open load valve completely in the hydraulic tester
to minimize the possibility of damaging components.
When using tester with pressure and flow capabili-
Operate all hydraulic controls to relieve system
pressure and avoid injury from pressurized hy-
draulic oil. Controls must be operated with the
ignition switch inOFF.Remove key from the igni-
tion switch.
6. Install fittings finger tight and far enough to make
sure that they are not cross-threaded before tightening
them with a wrench.
7.
parts from contacting and damaging the hoses or tester.
Position tester hoses to prevent rotating machine
WARNING
Before disconnecting or performing any work
on the hydraulic system, all pressure in the
system must be relieved and all rotating ma-
chine parts must be stopped. Stop engine;
lower or support attachments.
8.
necting test equipment, make sure tank is full.
Check oil level in the hydraulic reservoir. After con-
9.
binding, or broken parts.
Check control linkages for improper adjustment,
10.All
hydraulic tests should be made with the hydraulic
oil at normal operating temperature.
Hydraulic System
Page 4 - 36
Reelmaster 6500-D/6700-D
Categories | Lawn Mower Manual, Toro Lawn Mower Manual |
---|---|
Tags | Toro Reelmaster 6500-D, Toro Reelmaster 6700-D |
Download File |
|
Document Type | Service Manual |
Language | English |
Product Brand | Toro. Customer Service Representatives are available by phone:
Monday - Friday 7:30 a.m. to 9:00 p.m. (CDT) - Saturday 8:00 a.m. to 8:00 p.m. (CDT) - Sunday 10:00 a.m. to 8:00 p.m. (CDT)
Canada 1-888-225-4886 USA 1-888-384-9939, Lawn Mower |
Product Type | Walk Behind Mower |
Engine Manufacturer | Toro |
Document File Type | |
Publisher | toro.com |
Wikipedia's Page | Toro Company |
Copyright | Attribution Non-commercial |
(0 votes, average: 0 out of 5)