Toro 01084SL Rev F Service Manual Reelmaster 6500 D 6700 D Preface NOTE For Machines With Serial

Service and Repairs
NOTE:  For more  component repair  information, see
the Kubota WorkshopManual, Diesel Engine, 05 Series
at the end of Chapter 3 - Kubota Diesel Engines.
Battery Storage
If the machine will be stored for more than 30 days
4.  Store battery ina cool atmosphere toavoid quick de-
terioration of the battery charge.
1.
Remove the battery and charge it fully (see Battery
Service).
5.  To help prevent the battery from freezing, make sure
it is fully charged (see Battery Service).
2.
Either store battery on a shelf or on the machine.
3.
Leave cables disconnected ifthe battery is stored on
the machine.
Battery Care
1.
Battery  electrolyte  level  must  be  properly main-
B.  Coat battery  posts and  cable  connectors with
Grafo  112X   (skin-over)  grease   (Toro  Part   No.
505-165) or petroleum jelly to prevent corrosion.
tained. The top of the battery must be kept clean. lf the
machine is stored in a location where temperatures are
extremely high, the battery will run  down more rapidly
than if the machine is stored in a location where temper-
atures are cool.
3.
Battery cables must be tight on terminals to provide
good electrical contact.
WARNING
WARNING
Connecting cables to the wrong post could re-
sult in  personal injury and/or  damage to the
electrical system.
Wear safety goggles and rubber gloves when
working with electrolyte.  Charge battery in  a
well  ventilated  place   so  gasses  produced
while charging can dissipate. Since the gases
are explosive, keep open flames and electrical
sparks away from the battery;  do not smoke.
Nausea may result ifthe gasesare inhaled.Un-
plug charger from electrical outlet before con-
necting or disconnecting charger  leads to or
from battery posts.
4.
If corrosion occurs at terminals, disconnect cables.
Always  disconnect  negative  (-)   cable  first.  Scrape
clamps  and terminals  separately.  Reconnect  cables
with positive (+) cable first. Coat battery posts and cable
connectors with  Grafo 112X  (skin-over) grease (Toro
Part No. 505-165) or  petroleum jelly to prevent corro-
sion.
IMPORTANT:  Do not remove  fill caps while clean-
ing.
5.
and every 30 days if machine is in storage.
Check electrolyte  level every  25 operating  hours,
2.
hours of operation.  Keep terminals and entire  battery
case clean because a dirty battery will discharge slowly.
Check battery  condition  weekly or  after every  50
6.
ter. Do not fill cells above the fill line.
Maintain cell level with distilled or demineralized wa-
A.  Clean battery  by  washing  entire  case  with a
solution of baking soda and water. Rinse with clear
water.
Reelmaster 6500-D/6700-D
Electrical System (Rev. C)
Page 5 - 37   Rev. E
Product Specification
CategoriesLawn Mower Manual, Toro Lawn Mower Manual
Tags,
Download File
Please Enter the Security Characters Shown Below. Letters are Case Sensitive. Your download link will appear upon completing this step.
- 328 pages
Document TypeService Manual
LanguageEnglish
Product BrandToro. Customer Service Representatives are available by phone: Monday - Friday 7:30 a.m. to 9:00 p.m. (CDT) - Saturday 8:00 a.m. to 8:00 p.m. (CDT) - Sunday 10:00 a.m. to 8:00 p.m. (CDT)
Canada 1-888-225-4886 USA 1-888-384-9939, Lawn Mower
Product TypeWalk Behind Mower
Engine ManufacturerToro
Document File TypePDF
Publishertoro.com
Wikipedia's PageToro Company
CopyrightAttribution Non-commercial
(0 votes, average: 0 out of 5)

Submit your review (optional)
(will not be displayed)
* Required Field

Leave a Reply

Your email address will not be published. Required fields are marked *

*
*
Website