Toro 01084SL Rev F Service Manual Reelmaster 6500 D 6700 D Preface NOTE For Machines With Serial

Glow Plug System Test
This is a fast, simple test that can help you determine a
Glow Plug  system’s integrity  and operation. The  test
should be run  anytime hard starting (cold) is  encoun-
tered on a diesel engine equipped with a Glow system.
Remember-thereare2typesofGlowPlugsystemsthat
Toro uses:
Test instructions: Properly connect inductive Ammeter
to the multimeter (refer to manufacturer’s instructions).
Set multimeter on Volts scale. With the key off (or Glow
Switch  in off  position), place  the  inductive Ammeter
around the  main glow plug power  supply wire(s) and
readmeterpriortoactivatingGlowsystem.AdjustMeter
to read zero (if applicable). Cycle the Glow Plug system
at least two times (per instructions in Operator’s Manu-
al) and record the final results.
1.
Systems with resistors (Glow Plug Indicators) in se-
ries (Reelmaster 450/4500-D,  Groundsmaster 325-D,
etc.).
Typical specifications for systems without resistors:
2.
6700-D
Reelmaster 5100/5300-D, etc.).
Systems  without   resistors  (Reelmaster   6500-D/
, Reelmaster  3500-D,  Groundsmaster 455-D,
#
of Glow Plugs
Amps Draw (10%)
20 Amps
2
3
4
Tool(s) required: Digital Multimeter and/or inductive
Ammeter (AC/DC Current Transducer).
30 Amps
40 Amps
Individual Glow Plug resistance (all models) -
.3-.4 Ohms (cold)
Starting System Test
This is an excellent test to use when a  “slow crank/no
start” problem is encountered. It will tell you if the prob-
lem is due to an electrical open, short or high resistance
in the starter circuit.
Set multimeter on Volts scale. With the key off place the
inductive Ammeter around the main negative (-) Battery
Cable and read meter prior to activating the Starter sys-
tem. Adjust Meter to read zero (if applicable). Crank the
engineforatleast3secondsandrecordtheresults.Typ-
ical Starter  System Draw for  the Reelmaster  6500-D
and 6700-D is 225 Amps at 65_F.
Note:
The Battery condition and state of charge must
checked before testing the starter system.
Tool(s) required: Digital Multimeter and/or Inductive
Ammeter (AC/DC Current Transducer).
If current draw is significantly higher than listed - check
for shorted condition. If current draw is significantly low-
er than listed - check for high resistance.
Test instructions: Properly connect inductive Ammeter
to the multimeter (refer to manufacturers instructions).
Electrical System (Rev. C)
Reelmaster 6500-D/6700-D
Page 5 - 18
Product Specification
CategoriesLawn Mower Manual, Toro Lawn Mower Manual
Tags,
Download File
Please Enter the Security Characters Shown Below. Letters are Case Sensitive. Your download link will appear upon completing this step.
- 328 pages
Document TypeService Manual
LanguageEnglish
Product BrandToro. Customer Service Representatives are available by phone: Monday - Friday 7:30 a.m. to 9:00 p.m. (CDT) - Saturday 8:00 a.m. to 8:00 p.m. (CDT) - Sunday 10:00 a.m. to 8:00 p.m. (CDT)
Canada 1-888-225-4886 USA 1-888-384-9939, Lawn Mower
Product TypeWalk Behind Mower
Engine ManufacturerToro
Document File TypePDF
Publishertoro.com
Wikipedia's PageToro Company
CopyrightAttribution Non-commercial
(0 votes, average: 0 out of 5)

Submit your review (optional)
(will not be displayed)
* Required Field

Leave a Reply

Your email address will not be published. Required fields are marked *

*
*
Website