Lower Cutting Units
Thehydraulic pumpassembly isdrivenbyacoupling   at-
tached to the engine flywheel. The pump assembly con-
sists of  a three section  gear pump, a  gerotor charge
pump, and a variable displacement piston pump.
The lowering speed of the cutting units are regulated by
several flow  control valves. Location  of these control
valves depend on the machine as follows:
1.
On RM--6500--D machines with serial number below
Gear pump section  (P3) provides oil flow through  the
steering control valve and lift manifold to all cutting unit
liftcylinders.Maximumcircuitpressure(1500PSI/104.0
bar) is limited by a relief valve in the gear pump (R3).
280000000, two adjustable flow control valves regulate
lift cylinders #1, 4, and 5. These control valves  are lo-
cated on the main lift  manifold (one flow control regu-
lates lift cylinders #4 and 5). The adjustable flow control
valve that regulates lift cylinders #2 and 3 is located in
the rear of the traction unit.
When the cutting units  are in the raised position, flow
from the gear pump (P3)  passes through the steering
controlvalveandintotheliftmanifold.Allliftmanifoldso-
lenoid valves are de-energized and  flow is directed to
the hydraulic reservoir. An electrically activated flow di-
vider (FD1)  is also de-energized, preventing  flow be-
tween the #4 and 5 lift cylinders.
2.  OnRM--6500--Dmachines  withserialnumberabove
280000000, three adjustable flow control valves in the
lift control manifold regulate the lift cylinders. One con-
trol valve regulates cylinder #1, a second controls cylin-
ders #2 and 3 and the third controls cylinders #4 and 5.
To lower the cutting units, solenoid valves (SV3), (SV4),
(SV5), (SV6), (SV7), and (SV8) energize along with so-
lenoid  valve (SV1)  and flow  divider  (FD1). Solenoid
valve (SV2) is in its normally de-energized position, and
directs oil flow to the piston end of the lift cylinders. Hy-
draulic pressure against the piston side of the cylinder
causes the shafts to extend, and lower the cutting units.
When the solenoids and  the flow divider are de-ener-
gized, the lift cylinders are held in the lowered position.
3.  On RM--6700--D machines with serial number below
280000000, four adjustable flow control valves regulate
lift cylinders #1, 4, 5, 6, and 7. These control valves are
located on the main lift manifold (one flow control regu-
lates lift cylinders #4 and 5). The adjustable flow control
valve that regulates lift cylinders #2 & 3 is located in the
rear of the traction unit.
4.
OnRM--6700--Dmachines  withserialnumberabove
five adjustable flow control valves in the lift
280000000,
Pressure to the  lift manifold can be  monitored at port
(G3).
control manifold regulate the lift cylinders. One control
valve regulates cylinder #1, the second controls  cylin-
ders #2 and 3, the third controls cylinders #4 and 5, the
fourth controls cylinder #6 and the fifth controls cylinder
#7.
Reelmaster 6500-D/6700-D
Page 4 - 17  Rev. F
Hydraulic System
Product Specification
CategoriesLawn Mower Manual, Toro Lawn Mower Manual
Tags,
Download File
Please Enter the Security Characters Shown Below. Letters are Case Sensitive. Your download link will appear upon completing this step.
- 328 pages
Document TypeService Manual
LanguageEnglish
Product BrandToro. Customer Service Representatives are available by phone: Monday - Friday 7:30 a.m. to 9:00 p.m. (CDT) - Saturday 8:00 a.m. to 8:00 p.m. (CDT) - Sunday 10:00 a.m. to 8:00 p.m. (CDT)
Canada 1-888-225-4886 USA 1-888-384-9939, Lawn Mower
Product TypeWalk Behind Mower
Engine ManufacturerToro
Document File TypePDF
Publishertoro.com
Wikipedia's PageToro Company
CopyrightAttribution Non-commercial
(0 votes, average: 0 out of 5)

Submit your review (optional)
(will not be displayed)
* Required Field

Leave a Reply

Your email address will not be published. Required fields are marked *

*
*
Website