Toro 06148SL Rev B Reelmaster 5210 5410 5510 5610 Service Manual

Mow Control Manifold Service
Make sure the manifold isthoroughly cleaned before
C. Push spool down until  O--ring and back--up ring
are exposed on bottom  of mow manifold. Remove
lower O--ring and back--up ring from spool.
1.
removing any cartridge valve.
D. Pull spool up and out of mow manifold. Remove
O--rings and back--up ring from spool.
2.
nutsecuringsolenoidcoiltothecartridgevalve.Careful-
ly slide solenoid coil off the valve.
If solenoid cartridge valve is being serviced, remove
E.  Discard removed O--rings and back--up rings.
3.
move rotary handle from valve stem (Fig. 63):
If flow control cartridge valve is  being serviced, re-
8
A.  Loosen two (2)  set screws  that secure  handle
cap.
2
6
B.  Remove screw  and  then  lift handle  cap  from
valve.
9
10
7
C. Locate  and   retrieve  detent  pin,  compression
spring,  bushing and  lip seal.  The  sleeve bearing
should stay in the cap.
11
4
3
5
D. Loosen  two (2)  set screws  that secure handle
base to flow control valve and remove base.
1
CAUTION
Figure 63
Before opening hydraulic system, operate all hy-
draulic controls to relieve system pressure and
avoid injury from pressurized hydraulic oil. See
Relieving Hydraulic System Pressure in the Gen-
eral Information section of this chapter.
1.
2.
3.
4.
5.
6.
Handle base
Handle cap
7.
8.
9.
Set screw (2 used)
Screw
Detent pin
Lip seal
Compression spring
Bushing
10. Sleeve bearing
11. Flow control valve
Set screw (2 used)
IMPORTANT: Use  care  when  removing  cartridge
valves. Slight bending or distortion of the stem tube
can cause binding and malfunction. Make sure that
deep well socket fully engages the valve base.
5
4
2
4
2
3
4.
Using a  deep well socket,  remove cartridge valve
from manifold. Note correct location of O--rings, sealing
rings and backup  rings. Remove and  discard seal kit
from valve.
1
1
IMPORTANT: Before removing mow/backlap spool
from mow manifold, remove backlap switch, dowel
pin and ball.
UP
5.
If necessary, remove mow/backlap spool from mow
manifold (Fig. 64):
3
4
A.  Remove backlap switch from mow manifold be-
foreremoving mow/backlap spool(Fig.65).Remove
dowel pin and ball from manifold port after switch is
removed. Remove and discard O--ring from switch.
3
4
5
Figure 64
1.
2.
3.
Mow/backlap spool
Handle
4.
5.
Back--up ring
Retaining ring
B.  Remove lower retaining ring from mow/backlap
spool. Raise mow/backlap spool to allow access to
retaining ring on upper end of spool. Remove upper
retaining ring.
O--ring
Reelmaster 5010 Series
Page 4 -- 77    Rev. B
Hydraulic System
Product Specification
CategoriesLawn Mower Manual, Sprinkler and Irrigation Manuals, Toro Sprinkler and Irrigation Manuals
Tags, , ,
Download File
Please Enter the Security Characters Shown Below. Letters are Case Sensitive. Your download link will appear upon completing this step.
- 292 pages
Document TypeCatalog, Service Manual
LanguageEnglish
Product BrandToro. Customer Service Representatives are available by phone: Monday - Friday 7:30 a.m. to 9:00 p.m. (CDT) - Saturday 8:00 a.m. to 8:00 p.m. (CDT) - Sunday 10:00 a.m. to 8:00 p.m. (CDT)
Canada 1-888-225-4886 USA 1-888-384-9939, Lawn Mower
Document File TypePDF
Publishertoro.com
Wikipedia's PageToro Company
CopyrightAttribution Non-commercial
(1 votes, average: 4 out of 4)
Lawn and Garden readers have rated Toro 06148SL Rev B Reelmaster 5210 5410 5510 5610 Service Manual 4.0 out of 4.0 based on 1 product reviews.
Submit your review (optional)
(will not be displayed)
* Required Field

Toro 06148SL Rev B Reelmaster 5210 5410 5510 5610 Service Manual SKU UPC Model
Alfredo Gonzalez on Jun 06, 2014.

i hope is going to work


Leave a Reply

Your email address will not be published. Required fields are marked *

*
*
Website