High Temperature Shutdown Switch
The high temperature shutdown switch is located on the
water pump  housing (Fig. 55).  The high temperature
5.  Replace shutdown  switch if  specifications are not
met.
shutdown switch is normally open and closes when en-
gine coolant temperature reaches approximately 239oF
6.
the engine housing.
After testing is complete, install shutdown switch to
(115
oC). When excessive coolant temperature causes
the shutdown switch to close,  the engine shuts down.
There is a tan wire attached to the shutdown switch.
A.  Clean threads of housing and switch thoroughly.
Apply thread sealant to the threads of the switch.
NOTE:  If excessive  coolant temperature  causes en-
gine shutdown, the operator can restart the engine to al-
low the machine to be moved a short distance. After a
restart in this condition, the engine will run for approxi-
mately 10 seconds before the engine shuts down again.
B.  Thread switch  into the housing.  Torque switch
from 22 to 28 ft--lb (30 to 39 N--m).
C. Reconnect harness wire to switch.
7.
8.
Fill engine cooling system.
Lower and secure hood.
The Electronic Control Module (ECM) monitors the op-
eration of the high temperature  shutdown switch. The
switch and its circuit wiring should be tested as an ECM
input with the Diagnostic Display (see Special Tools and
Troubleshooting in this chapter).
If excessive  coolant temperature caused  the ECM to
shut down the engine, the Diagnostic light can be used
to identify the fault (see Diagnostic Light in the Trouble-
shooting section of this chapter).
Testing
1.
stop engine, apply parking brake and remove key from
ignition switch. Open hood to gain access to engine.
Park machine on a level surface, lower cutting units,
1
CAUTION
Figure 55
High temperature switch
1.
Make sure  engine is cool  before removing  the
temperature switch from engine.
2.
high temperature shutdown switch from the engine.
Lower the coolant level inthe engine and remove the
3.
thermometer and slowly heat the oil (Fig. 56).
Put the end of the switch in a container of oil with a
CAUTION
Figure 56
Handle the hot oil with extreme  care to prevent
personal injury or fire.
4.
(ohms setting)  as the oil  temperature increases.  The
Check resistance  of  the switch  with a  multimeter
hightemperature shutdown switch isnormally openand
should close from 234o to 244oF (112o to 118oC).
Electrical System
Page 5 -- 42
Reelmaster 5010 Series
Product Specification
CategoriesLawn Mower Manual, Sprinkler and Irrigation Manuals, Toro Sprinkler and Irrigation Manuals
Tags, , ,
Download File
Please Enter the Security Characters Shown Below. Letters are Case Sensitive. Your download link will appear upon completing this step.
- 292 pages
Document TypeCatalog, Service Manual
LanguageEnglish
Product BrandToro. Customer Service Representatives are available by phone: Monday - Friday 7:30 a.m. to 9:00 p.m. (CDT) - Saturday 8:00 a.m. to 8:00 p.m. (CDT) - Sunday 10:00 a.m. to 8:00 p.m. (CDT)
Canada 1-888-225-4886 USA 1-888-384-9939, Lawn Mower
Document File TypePDF
Publishertoro.com
Wikipedia's PageToro Company
CopyrightAttribution Non-commercial
(1 votes, average: 4 out of 4)
Lawn and Garden readers have rated Toro 06148SL Rev B Reelmaster 5210 5410 5510 5610 Service Manual 4.0 out of 4.0 based on 1 product reviews.
Submit your review (optional)
(will not be displayed)
* Required Field

Toro 06148SL Rev B Reelmaster 5210 5410 5510 5610 Service Manual SKU UPC Model
Alfredo Gonzalez on Jun 06, 2014.

i hope is going to work


Leave a Reply

Your email address will not be published. Required fields are marked *

*
*
Website