Toro 06148SL Rev B Reelmaster 5210 5410 5510 5610 Service Manual

TURFDEFENDER V1.0
DIAGNOSTIC ACE
1
OUTPUT / INPUT
VALVE ON /
FLOAT LEVEL
INPUT / OUTPUT
TANK LEVEL HIGH /
FLOAT LOW
(TOP)
VALVE OPEN CIRCUIT /
FLOAT LEVEL 2
TANK LEVEL OK  /
RESET TOO OFTEN
VALVE SHORT CIRCUIT/
FLOAT LEVEL 3
TANK LEVEL LOW /
(UNUSED)
Diagnostic Display Functions
ALARM ON /
FLOAT LEVEL 4
(UNUSED) /
DRIP--DROP
ALARM OPEN CIRCUIT /
FLOAT LEVEL 5
(UNUSED) /
(UNUSED) /
(UNUSED) /
(UNUSED) /
(UNUSED)
(UNUSED)
(UNUSED)
(UNUSED)
1.   Overlay decal (English shown)
2.
3.
4.
“Inputs Displayed” LED (Red)
“Outputs Displayed” LED (Green)
Toggle button
ALARM SHORT CIRCUIT/
FLOAT LEVEL 6
SELF DIAGNOSTIC /
FLOAT LEVEL 7
2
3
DATA LINE /
FLOAT LEVEL 8
RATE TOO HIGH /
FLOAT LEVEL 9
INPUTS DISPLAYED
CUMULATIVE RATE /
FLOAT
LEVEL
OUTPUTS DISPLAYED
4
(BOTTOM)

Figure 14
94--5386
TURFDEFENDER V1.0
DIAGNOSTIC ACE
Using “Inputs Displayed” (Red Text)
1
2
3
OUTPUT / INPUT
VALVE ON /
FLOAT LEVEL
INPUT / OUTPUT
TANK LEVEL HIGH /
FLOAT LOW
1.
2.
LED lit if tank level is too high
LED lit if tank level is OK
(TOP)
VALVE OPEN CIRCUIT /
FLOAT LEVEL 2
TANK LEVEL OK  /
RESET TOO OFTEN
3.   LED lit if tank level is too low
VALVE SHORT CIRCUIT/
FLOAT LEVEL 3
TANK LEVEL LOW /
(UNUSED)
4.
One or two LED’s lit displaying
relative position of the TurfDefender’s
internal float (Normal level is combin--
ation of levels 3 and/or 4)
ALARM ON /
(UNUSED) /
DRIP--DROP
FLOAT LEVEL 4
ALARM OPEN CIRCUIT /
FLOAT LEVEL 5
(UNUSED) /
(UNUSED) /
(UNUSED) /
(UNUSED) /
(UNUSED)
(UNUSED)
(UNUSED)
(UNUSED)
ALARM SHORT CIRCUIT/
FLOAT LEVEL 6
SELF DIAGNOSTIC /
FLOAT LEVEL 7
5.
“Inputs Displayed” LED “ON” (Red)
4
5
DATA LINE /
FLOAT LEVEL 8
RATE TOO HIGH /
FLOAT LEVEL 9
INPUTS DISPLAYED
Normal Operation:
a.  “Tank Level OK” LED lit
b.  1 or 2 LED’s lit on left column
CUMULATIVE RATE /
FLOAT
OUTPUTS DISPLAYED
LEVEL
(BOTTOM)

94--5386
Figure 15
TURFDEFENDER V1.0
DIAGNOSTIC ACE
OUTPUT / INPUT
VALVE ON /
FLOAT LEVEL
INPUT / OUTPUT
TANK LEVEL HIGH /
FLOAT LOW
(TOP)
Using “Outputs Displayed” (Green Text)
VALVE OPEN CIRCUIT /
FLOAT LEVEL 2
TANK LEVEL OK  /
RESET TOO OFTEN
VALVE SHORT CIRCUIT/
FLOAT LEVEL 3
TANK LEVEL LOW /
(UNUSED)
Normal Operation:
ALARM ON /
FLOAT LEVEL 4
(UNUSED) /
DRIP--DROP
a.  “Valve On” LED lit steadily
b.  “Self Diagnostic” LED lit steadily
c.  “Data Line” LED lit steadily
d.  “Alarm On” LED lit temporarily
ALARM OPEN CIRCUIT /
FLOAT LEVEL 5
(UNUSED) /
(UNUSED) /
(UNUSED) /
(UNUSED) /
(UNUSED)
(UNUSED)
(UNUSED)
(UNUSED)
ALARM SHORT CIRCUIT/
FLOAT LEVEL 6
SELF DIAGNOSTIC /
FLOAT LEVEL 7
DATA LINE /
FLOAT LEVEL 8
Problem Diagnosed:
RATE TOO HIGH /
FLOAT LEVEL 9
INPUTS DISPLAYED
The appropriate LED will blink to
identify the problem
CUMULATIVE RATE /
FLOAT
LEVEL
OUTPUTS DISPLAYED
(BOTTOM)

Figure 16
94--5386
Reelmaster 5010 Series
Page 5 -- 17
Electrical System
Product Specification
CategoriesLawn Mower Manual, Sprinkler and Irrigation Manuals, Toro Sprinkler and Irrigation Manuals
Tags, , ,
Download File
Please Enter the Security Characters Shown Below. Letters are Case Sensitive. Your download link will appear upon completing this step.
- 292 pages
Document TypeCatalog, Service Manual
LanguageEnglish
Product BrandToro. Customer Service Representatives are available by phone: Monday - Friday 7:30 a.m. to 9:00 p.m. (CDT) - Saturday 8:00 a.m. to 8:00 p.m. (CDT) - Sunday 10:00 a.m. to 8:00 p.m. (CDT)
Canada 1-888-225-4886 USA 1-888-384-9939, Lawn Mower
Document File TypePDF
Publishertoro.com
Wikipedia's PageToro Company
CopyrightAttribution Non-commercial
(1 votes, average: 4 out of 4)
Lawn and Garden readers have rated Toro 06148SL Rev B Reelmaster 5210 5410 5510 5610 Service Manual 4.0 out of 4.0 based on 1 product reviews.
Submit your review (optional)
(will not be displayed)
* Required Field

Toro 06148SL Rev B Reelmaster 5210 5410 5510 5610 Service Manual SKU UPC Model
Alfredo Gonzalez on Jun 06, 2014.

i hope is going to work


Leave a Reply

Your email address will not be published. Required fields are marked *

*
*
Website