Diagnostic Display
Reelmaster 5010 machines are equipped with an Elec-
tronic Control Module (ECM) which controls machine
electrical functions. The ECM monitors various input
switches (e.g. ignition switch, seat switch, etc.) and en-
ergizes outputs to actuate solenoids or relays for the re-
quested machine function.
5. The “inputs displayed” LED, on lower right column of
theDiagnosticDisplay,shouldbeilluminated.If“outputs
displayed”LEDisilluminated,pressthetogglebuttonon
the Diagnostic Display to change to “inputs displayed”
LED.
6.
The Diagnostic Display will illuminate the LED
For the ECM to control the machine as desired, each of
the input switches, output solenoids and relays must be
connected and functioning properly.
associatedwitheachoftheinputswhenthatinputswitch
is closed. Individually,change each ofthe switches from
open to closed (i.e., sit on seat, press traction pedal,
etc.), and notethattheappropriate LEDon theDiagnos-
ticDisplaywillilluminatewhenthecorresponding switch
is closed. Repeat on each switch that is possible to be
changed by hand.
The Diagnostic Display is a tool to help the technician
verify correct electrical functions of the machine.
IMPORTANT: The Diagnostic Display must not be
left connected to the machine. It is not designed to
withstand the environment of the machine’s every
dayuse.WhenuseoftheDiagnosticDisplayiscom-
pleted, disconnect it from the machine and recon-
nect loopback connector to harness connector.The
machine will not operate without the loopback con-
nector installed on the harness. Store the Diagnos-
tic Display in a dry, secure, indoor location, not on
machine.
7.
If appropriate LED does not toggle on and off when
switch state is changed, check all wiring and connec-
tions to that switch and/or test switch (see Component
Testing in this chapter). Replace any defective switches
and repair any damaged wiring.
1
Verify Diagnostic Display Input Functions
3
CAUTION
The interlock switches are for the protection of
the operator and bystanders and to ensure cor-
rect operation of the machine. Do not bypass or
disconnect switches. Check the operation of the
interlockswitchesdailyforproperoperation.Re-
place any malfunctioning switches before oper-
ating the machine.
2
Figure 8
3.
1.
2.
ECM location
Loopback connector
Harness connector
1.
units, stop the engine and engage the parking brake.
Park machine on a level surface, lower the cutting
1
2.
Open control panel cover. Locate wire harness and
connectors near ECM. Carefully unplug loop back con-
nector from harness connector (Fig. 8).
3.
nessconnector.Makesurecorrectoverlaydecalisposi-
tioned on the Diagnostic Display (Fig. 11).
ConnecttheDiagnosticDisplayconnectortothehar-
4.
Turn the ignition switch to the RUN position, but do
not start machine.
2
NOTE: The red text on the overlay decal refers to input
switches and the green text refers to outputs.
Figure 9
1.
Diagnostic display
2.
Loopback connector
Electrical System
Page 5 -- 6 Rev. A
Reelmaster 5010 Series
Categories | Lawn Mower Manual, Sprinkler and Irrigation Manuals, Toro Sprinkler and Irrigation Manuals |
---|---|
Tags | Toro 5210, Toro 5410, Toro 5510, Toro 5610 |
Download File |
|
Document Type | Catalog, Service Manual |
Language | English |
Product Brand | Toro. Customer Service Representatives are available by phone:
Monday - Friday 7:30 a.m. to 9:00 p.m. (CDT) - Saturday 8:00 a.m. to 8:00 p.m. (CDT) - Sunday 10:00 a.m. to 8:00 p.m. (CDT)
Canada 1-888-225-4886 USA 1-888-384-9939, Lawn Mower |
Document File Type | |
Publisher | toro.com |
Wikipedia's Page | Toro Company |
Copyright | Attribution Non-commercial |
(1 votes, average: 4 out of 4) Lawn and Garden readers have rated Toro 06148SL Rev B Reelmaster 5210 5410 5510 5610 Service Manual 4.0 out of 4.0 based on 1 product reviews.
i hope is going to work