Toro 06148SL Rev B Reelmaster 5210 5410 5510 5610 Service Manual

A.  Measure the specific gravity of each  cell with a
hydrometer.  Draw  electrolyte  in  and  out   of  the
hydrometer barrel prior to taking a reading to warm--
up the hydrometer. At the same time take the tem-
perature of the cell.
C. Make surebattery terminals arefreeofcorrosion.
D. Measure  the temperature of  the center  battery
cell.
E.  Connect a battery load tester to the battery termi-
nals following the load tester manufacturer’s in-
structions.  Connect  a  digital  multimeter  to  the
battery terminals.
B.  Temperature correct each cell reading. For each
10
oF (5.5oC) above 80oF (26.7oC) add 0.004 to the
specific gravity reading. For each 10oF (5.5oC) be-
low 80oF (26.7oC) subtract 0.004  from the specific
F.  Applyatestloadof295amps(onehalftheCrank-
ing Performance  rating  of the  battery) for  15  se-
conds.
gravity reading.
Example: Cell Temperature
Cell Gravity
100oF
1.245
oF minus 80oF equals 20oF
oC minus 26.7oC equals 11.0oC)
oF multiply by 0.004/10oF equals 0.008
oC multiply by 0.004/5.5oC equals 0.008)
G. Take a voltage reading after 15 seconds, then re-
move the load.
100
(37.7
20
(11
H. Using  the table below,  determine the minimum
voltage for the cell temperature reading:
ADD (conversion above)
Correction to 80oF (26.7oC)
0.008
1.253
C. If the difference between the highest and lowest
cell specific gravity is 0.050 or greater or the lowest
cellspecificgravityislessthan1.225,chargethebat-
tery. Charge at the recommended rate and time giv-
en in Charging or until specific gravity of all cells is
Minimum
Voltage
Battery Electrolyte
Temperature
9.6
9.5
9.4
9.3
9.1
8.9
8.7
8.5
70oF (and up)
60oF
21.1oC (and up)
15.6oC
10.0oC
4.4oC
1.225
orgreater withthedifferenceinspecificgravity
50oF
40oF
30oF
20oF
10oF
0oF
between the highest and lowest cell less than 0.050.
If these charging conditions can not be met, replace
the battery.
--1.1oC
--6.7oC
--12.2oC
--17.8oC
3.
Perform a  high--discharge test  with an  adjustable
load tester.
Thisisoneofthemostreliablemeansoftestingabattery
asitsimulatesthecold--crankingtest.Acommercialbat-
tery load tester is required to perform this test.
I.   If the test voltage is below the minimum, replace
the battery. If the test voltage is at or above the mini-
mum, return the battery to service.
CAUTION
Follow  the battery  load  tester  manufacturer’s
instructions when using a battery load tester.
A.  Check the voltage across  the battery terminals
prior to testing the battery. If the voltage is less than
12.4
VDC, recharge the battery.
B.  If the battery has recently been charged, remove
the battery  surface  charge before  performing the
loadtest.Disconnect  theengine fuelstopsolenoidto
prevent the engine from starting. Engage the starter
motor  for 10  seconds  to remove  battery  surface
charge. Reconnect the fuel stop solenoid.
Electrical System
Page 5 -- 48
Reelmaster 5010 Series
Product Specification
CategoriesLawn Mower Manual, Sprinkler and Irrigation Manuals, Toro Sprinkler and Irrigation Manuals
Tags, , ,
Download File
Please Enter the Security Characters Shown Below. Letters are Case Sensitive. Your download link will appear upon completing this step.
- 292 pages
Document TypeCatalog, Service Manual
LanguageEnglish
Product BrandToro. Customer Service Representatives are available by phone: Monday - Friday 7:30 a.m. to 9:00 p.m. (CDT) - Saturday 8:00 a.m. to 8:00 p.m. (CDT) - Sunday 10:00 a.m. to 8:00 p.m. (CDT)
Canada 1-888-225-4886 USA 1-888-384-9939, Lawn Mower
Document File TypePDF
Publishertoro.com
Wikipedia's PageToro Company
CopyrightAttribution Non-commercial
(1 votes, average: 4 out of 4)
Lawn and Garden readers have rated Toro 06148SL Rev B Reelmaster 5210 5410 5510 5610 Service Manual 4.0 out of 4.0 based on 1 product reviews.
Submit your review (optional)
(will not be displayed)
* Required Field

Toro 06148SL Rev B Reelmaster 5210 5410 5510 5610 Service Manual SKU UPC Model
Alfredo Gonzalez on Jun 06, 2014.

i hope is going to work


Leave a Reply

Your email address will not be published. Required fields are marked *

*
*
Website