Reel Drive Motor Cross--Over Relief Pressure Test (Reelmaster 5510 and 5610)
Use a tee fitting to install
pressure gauge in both inlet
and outlet lines of motor
being tested.
NOTE: Inlet is front hose.
Outlet is rear hose.
R11
R11
R11
Front
Hose
Front
Hose
Front
Hose
Rear
Hose
R11
R11
R11
M4
M1
M5
M2
Rear
Hose
Rear
Hose
BKLP2
MOW CONTROL
MANIFOLD
High Pressure
Low Pressure
Flow
RM5510/5610 FRONT MOW CIRCUIT SHOWN
Figure 38
NOTE: One way to find a faulty reel motor is to have
another person observe the machine while mowing in
dense turf. A faulty motor will run slower, produce fewer
clippings and may cause clip marks (a choppy appear-
ance) on the turf.
NOTE: Before testing the reel drive motor cross--over
reliefpressure,makesurethatreelmotor isingoodcon-
ditionbyperforming theReelDriveMotorEfficiencyTest
(see Reel Drive Motor Efficiency Test in this section).
IMPORTANT: DO NOT perform the Reel Drive Motor
Cross--Over Relief Pressure Test on Reelmaster
5210
and 5410 machines. The reel motors on these
machines do not have cross--over relief valves.
Hydraulic System
Page 4 -- 42 Rev. B
Reelmaster 5010 Series
Categories | Lawn Mower Manual, Sprinkler and Irrigation Manuals, Toro Sprinkler and Irrigation Manuals |
---|---|
Tags | Toro 5210, Toro 5410, Toro 5510, Toro 5610 |
Download File |
|
Document Type | Catalog, Service Manual |
Language | English |
Product Brand | Toro. Customer Service Representatives are available by phone:
Monday - Friday 7:30 a.m. to 9:00 p.m. (CDT) - Saturday 8:00 a.m. to 8:00 p.m. (CDT) - Sunday 10:00 a.m. to 8:00 p.m. (CDT)
Canada 1-888-225-4886 USA 1-888-384-9939, Lawn Mower |
Document File Type | |
Publisher | toro.com |
Wikipedia's Page | Toro Company |
Copyright | Attribution Non-commercial |
(1 votes, average: 4 out of 4) Lawn and Garden readers have rated Toro 06148SL Rev B Reelmaster 5210 5410 5510 5610 Service Manual 4.0 out of 4.0 based on 1 product reviews.
i hope is going to work